Answer: (1) Cause analysis.

1) Air filter is clogged;

2) Intake valve is not functioning properly;

3) Pressure maintenance valve is not functioning properly;

4) Oil fine separator is clogged;

5) Discharge solenoid valve is leaking;

6) Improper adjustment of the capacity regulating valve;

7) User pipe network has leakage;

8) Pressure switch is set too low or pressure switch is faulty;

9) Pressure sensor or pressure gauge input hose is leaking;

10) The actual gas consumption is greater than the unit output gas volume.

(2) Elimination method.

1) Clean and replace;

2) Check whether the intake valve is fully open and eliminate the fault;

3) After disassembly, check whether it is worn, stuck, or spring fatigued;

4) Replace;

5) Disassemble and clean. Replace if necessary;

6) Re-adjust the valve position of the capacity regulating valve;

7) Eliminate the leak;

8) Reset;

9) Replace the meter tube;

10) Check the gas consumption.